At the Heart of
Renal Care
Find out why we’re an established leader in renal care. Designed for the ICU.
Equipped for the HCP.
Why NxStage System One with NxView ?
®
™
Compact
Connected
Secure
Compact
References
Designed for improving the simplicity of acute renal replacement therapy. Explore the NxStage System One's Impact On:
Staff Workload
Interruptions
User Training
Setup
Filter Clotting
Connected
Secure
The NxStage System One S with NxView includes wireless capability. Access EMR records from any place in the ICU or hospital using the integrated Wi-Fi technology.
The System One S can easily be integrated with Epic,
Cerner , and other EMR providers.¹
®
®
Treatment data is permanently stored and retrievable, even in the event of a power loss or if the EMR system goes down.¹
Microsoft Windows 10 with built-in Windows Defender Antivirus is embedded on a locked drive, providing protection from viruses, malware, spyware, and other threats.¹
®
Uniquely designed volumetric balancing system provides fluid accuracy without the need for scales, eliminating scale-based alarms and interruptions due to emptying waste bags.
Effluent flows to an open drain line, eliminating interruptions in therapy due to emptying waste bags.
Intuitive controls designed to ensure ease of use and simplify user training.
Eliminates the need for an external water source and treatment systems so you can use it virtually anywhere in your facility.
Disposable cartridge is specifically designed to eliminate blood-air interfaces which may reduce the risk of filter clotting and related therapy interruptions.¹
Explore our system
The System One S with NxView
features are designed to simplify the delivery of the therapy.
References
Take a closer look
NxStage System One S with NxView provides therapy flexibility
Renal Replacement Therapy (RRT)
Slow Continuous Ultrafiltration (SCUF)
Therapeutic Plasma Exchange (TPE)
Why NxStage from Fresenius Medical Care?
Used by leading renal care hospitals in the U.S. as ranked by U.S. News & World Report.¹
Nearly 20 years experience in critical care.
Acquired by Fresenius Medical Care, the world’s leading provider of products and services for people with chronic kidney failure.
Trust an established leader to simplify your renal care.
Risks and Responsibilities
Renal replacement therapy, as with any medical therapy is not without risks. The decision of which therapy to use should be made by the physician, based on previous experience and on the individual facts and circumstances of the patient. There is no literature demonstrating one therapy is clinically better than another.¹ NxView is contraindicated as the sole method of monitoring a patient during treatment.
1. Kraus MA. Selection of Dialysate and Replacement Fluids and Management of Electrolyte and Acid-Base Disturbances. Seminars in Dialysis; Vol 22, No 2 (March-April) 2009 pp. 137-140.
Contact Us
LEARN MORE
1. Polaschegg, HD. Mechanical Aspects of Dialysis; The Extracorporeal Circuit. Seminars in Dialysis Vol. 8, No 5 (Sep-Oct) 1996 pp 299-304.
NxView Monitor
•
•
•
•
Intuitive touch screen navigation for operating, monitoring and troubleshooting.
Real-time treatment information.¹
96 hours of therapy graphing.¹
EMR connectivity with Wi-Fi capability.¹
Ergonomic Stand
•
•
Easy transport with push/pull handle.
Conveniently hang fluid bags at shoulder height.
Hang up to 29 L of fluid at once.¹
•
Cycler
•
No special electrical or plumbing needs so the System One S can be used anywhere in your facility.¹
Volumetric Balancing Technology
•
A uniquely designed volumetric fluid balancing system allows for accurate fluid balancing without the need for scales or waste bags.
Our simplified fluid management system allows the connection of multiple fluid bags (up to 29L of fluid) at once and direct-to-drain effluent disposal, designed to help reduce staff workload.¹
Cartridge
•
•
Simple drop in cartridge for easy set-up.
Easily switch between modalities without changing the cartridge.
NxStage cartridges are designed to eliminate blood-air interface, which may reduce the risk of filter clotting.
The PUREMA H filter technology allows for high clearances running in either hemofiltration or hemodialysis modes.
The cartridges include several ports to customize and support anticoagulation.
The CAR-505 includes a SecureClip
pre-attached to the arterial and
venous lines, designed to strengthen
patient connection and minimize
access tubing disconnects.
•
•
•
•
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
2. Polaschegg, HD. Mechanical Aspects of Dialysis; The Extracorporeal Circuit. Seminars in Dialysis Vol. 8, No 5 (Sep-Oct) 1996 pp 299-304.
NxView Monitor
Volumetric Balancing Technology
Cycler
Cartridge
Ergonomic Stand and IV Pole
1. Polaschegg, HD. Mechanical Aspects of Dialysis; The Extracorporeal Circuit. Seminars in Dialysis Vol. 8, No 5 (Sep-Oct) 1996 pp 299-304.
Renal Replacement Therapy (RRT)
With a broad range of flow rates, the System One S allows you to individualize the therapy based on the condition of the patient, including Continuous Renal Replacement Therapy (CRRT), Prolonged Intermittent Renal Replacement Therapy (PIRRT) or intermittent hemodialysis (IHD).¹
System One S flow rates :
Blood
Up to 600 mL/min
Prescription fluid
Up to 12 L/hr
UF/Fluid removal
Up to 2.4 L/hr
Slow Continuous Ultrafiltration (SCUF)
The System One S allows you to switch to Isolated Ultrafiltration without having to change the cartridge.
Therapeutic Plasma Exchange (TPE)
The NxStage System One S brings a well-established, simple membrane technology to TPE procedures. As membrane-based TPE becomes more frequently prescribed, an increasing number of physicians are using this therapy.
Advantages
Low extracorporeal blood volume (110 mL)
Needleless luer-activated valves maintain their microbial barrier properties based on test results of 140 activations, when used with an adequate disinfection procedure²
No blood-air interface in cartridge, designed to reduce risk of filter clotting
Prescription fluid
Up to 12 L/hr
UF/Fluid removal
Up to 2.4 L/hr
Safety
Renal Replacement Therapy (RRT)
Slow Continuous Ultrafiltration (SCUF)
Therapeutic Plasma Exchange (TPE)
•
•
Effectiveness
Up to 4.0 L of plasma exchange per hour
•
Simplicity
Volumetric control eliminates the need for scales and waste bags
Unique drop in cartridge design for quick TPE set-up
Up to nine connections for
replacement fluid
•
•
•
References
1. Data on File.
2. Robertsite 7-day Microbial Challenge Evaluation, P Miller, December 2007. Halkey-Roberts Corporation.
3. Polaschegg HD. The extracorporeal circuit. Semin Dial. 1995;8(5):299-304.
4. NxStage System One User Guide, NC4921 Rev. H 2020-01.
1,2
Blood flow rates:
Fluid Removal Rate:
Low-volume CAR-125-B with MedivatorsRenaflo filter:
10-200 mL/min
Up to 2.4 L/hr
Total extracorporeal blood volume:
© 2021 Fresenius Medical Care. All Rights Reserved. Fresenius Medical Care, the triangle logo, NxStage, and SystemOne are trademarks of Fresenius Medical Care Holdings, Inc. or its affiliated companies. All other trademarks are the property of their respective owners.
CAUTION: Federal law restricts this device to sale by or on the order of a physician. APM4051 Rev A
1. U.S. News & World Report. Top-Ranked Hospitals for Nephrology.
http://health.usnews.com/best-hospitals/rankings/nephrology. August 2020.
2. Fresenius Medical Care Annual Financial Report, 2020
HF-400: 83 mL
HF-700: 108 mL
HF-1200: 138 mL
10-600 mL/min
Up to 2.4 L/hr
——
CAR–505 Cartridge Express
CAR-125-B with
Medivators Renaflo filter
Blood flow rates:
Fluid Removal Rate:
Total extracorporeal blood volume:
The System One S can easily be integrated with Epic , Cerner and other EMR providers.
The System One S can easily be integrated with Epic , Cerner and other EMR providers.
®
CAR-125-B with Medivators®
Renaflo® filter
®
1. NxStage EMR Set Up Guide, NC8549 Rev. D 2020-01
®
171 mL
171 mL
The PUREMA H filter technology allows for high clearances running in either hemofiltration or hemodialysis modes.¹
The cartridges include several ports to customize and support anticoagulation.
The CAR-505 includes a SecureClip
pre-attached to the arterial and
venous lines, designed to strengthen
patient connection and minimize
access tubing disconnects.
™
1. Polaschegg HD. The extracorporeal circuit. Semin Dial. 1995;8(5):299-304.
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
•
2
1. Filter Membrane Webinars, parts 1 & 2, nxstage.com.
Data on file, Membrana GmbH, membrana.com.
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
Our cartridges allow a broad range of flow rates:
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
2. NxStage Cartridge IFU. NC45-0293 Rev. D.
3. NxStage CAR-125 IFU. NC45-0242 Rev. H.
3
1
•
2
4
1
1
1,3
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.
1
Volumetric Balancing Technology
•
•
A uniquely designed volumetric fluid balancing system allows for accurate fluid balancing without the need for scales or waste bags.
Our simplified fluid management system allows the connection of multiple fluid bags (up to 29L of fluid) at once and direct-to-drain effluent disposal, designed to help reduce staff workload.¹
1. NxStage System One User Guide, NC4921 Rev. H 2020-01.