More
Information
More
Choice
More
Protection
More
Accuracy
The CereLink ICP Monitoring System is more accurate than the leading competitor in terms of less drift over time
1,3
1
Accurate vs leading competitor
in terms of less drift over time
Less drift< ± 2.20mmHg over 7days
Camino Data not available after 5 days.
Camino average drift not available.
CereLink vs Camino®
Drift Over Time
1,2
More Accuracy
Due to Less Drift
CereLink ICP Sensor is MR Conditional
2*
MR Conditional Capability
More Protection
Patients can be safely scanned in 1.5T and 3T MR environments for ALL sensor configurations when following the MRI conditions as listed in the IFU
Prognostic MR imaging capability while CereLink ICP sensor is still implanted
MRI conditional reduces the need for compromises with CT
Pliable construction of the sensor allows for durability and resistance to breakage, or degradation in accuracy due to bending
CereLink ICP Sensor addresses the limitations of fiber optic sensors
Durable, Flexible ICP Sensors
More Choice
The size and flexibility of the transducer gives the physician greater choice of implantation and fixation methods - tunneling, bolting or ventricular placement
Real-time, digital streaming allows third-party access to full, high-fidelity ICP waveform data
Simple zeroing process provides accuracy, with one-touch transducer zeroing function
Data streaming and ease-of-use features
Advanced Data Presentation
More Information
Allows the user to reconnect the ICP Sensor to the same or different ICP Monitor without having to readjust the zero reference value
The CereLink ICP Monitor automatcally stores the zero-reference value in a memory element embedded in the CereLink ICP sensor
Customized data on-demand allows for visualization
of significant changes in the ICP and trends
Time Above Threshold and Histogram:
Time above threshold and histograms visualize time of ICP above a user-set threshold and time at specific ICP intervals.
Pressure Time Dosage (PTD):
PTD helps physicians better understand a patient’s ICP for targeted, individualized therapy
1,3
1. CereLink bench test shows (2 stdev) of ±2.2 mmHg over 7 days and 3.8mmHg (4 stdev) over 7 days.
2. Camino System IFU (A40256 Rev H)
1
2. CereLink system IFUs
1
1. CereLink system IFUs
1. CereLink system IFUs
1
1. CereLink system IFUs
*The CereLink ICP Sensor is MR Conditional and the CereLink ICP Monitor is contraindicated for use in a Magnetic Resonance (MR) environment. See Instructions for Use for complete product information and specific MRI Safety Information. Read and understand the IFU in its entirety prior to performing a Magnetic Resonance Imaging Procedure on a patient with an implanted CereLink® ICP Sensor. Failure to adhere to the Conditions for Safe Use may result in serious injury to the patient.