OnPoint’s Zolo Technologies delivers unique laser-based combustion monitoring and diagnostic capabilities for ultra-harsh environments to optimize the yield, efficiency, and safety of combustion applications.
Solutions across industrial domains.
OnPoint is a portfolio of digital solutions that deliver enhanced system performance through optimization technologies developed by proven experts in your domain.
Ready to learn more?
Contact us
Optimize combustion
AND TURN UP YOUR YIELD.
ZOLO is built on and leverages our decades of expertise in the combustion domain.
VISIT JOHNZINKHAMWORTHY.COM
ZoloSCAN Fast EAF Off-Gas Detection
ZoloSCAN 2 Install
ZoloSCAN Petrochemical & Refining
ZoloSCAN Steel Reheat Furnace
ZoloSCAN 2
ZoloSCAN Fast EAF Off-Gas Detection
ZoloSCAN 2 Install
ZoloSCAN Petrochemical & Refining
ZoloSCAN Steel Reheat Furnace
ZoloSCAN 2
Ethylene
Steam Generation
Electric Arc Furnace
Reforming
Basic Oxygen Furnace
Installation Base
Power Generation
Reheat Furnace
Ethylene
Reheat Furnace
Increased run lengths.
The ethylene cracking process requires precise temperature control to avoid "hot spots" and associated coking-induced downtime. A lack of measurements directly in the furnace makes it difficult to maintain an optimal temperature distribution to avoid localized tube plugging. ZoloSCAN provides the solution via real-time, in-furnace measurements of temperature, 02, H20 and CO enabling you to maintain a target combustion profile and extend cracker run-time.
DOWNLOAD LITERATURE
OPTIMIZED FURNACE COMBUSTION.
Small boilers are often used for converting local energy sources into process steam. Because these furnaces regularly operate with a variable fuel source or a fuel source for which the boiler was not designed (biomass, blast furnace gas, CO enriched CH4, etc.), optimal operation can be quite difficult to maintain. ZoloSCAN provides a solution via in-furnace, laser-based measurements of temperature, H20, CO, and 02 enabling the operator to maintain balanced and optimized furnace combustion.
Steam Generation
FAST EAF OFF-GAS DETECTION.
EAF steelmaking requires tight control of end-point carbon concentration and temperature for optimum product quality. The variable composition of scrap steel can make the control process difficult and often results in low-energy efficiency and/or high emissions due to sub-optimal combustion. Traditional off-gas monitors require significant on-site maintenance and calibration and do not provide a sufficiently fast response for operators to optimize the process. ZoloSCAN measures temperature, H2O, CO and CO2 in real-time, directly in the fourth hole duct using non-intrusive TDLAS technology. The ZoloSCAN delivers actionable, two-second updates of species concentrations and temperature that can be used to optimize post-combustion energy recovery and detect water leaks thereby improving EAF performance and safety.
DOWNLOAD LITERATURE
Electric Arc Furnace
EFFICIENT FURNACE OPERATION.
Reformers present a unique furnace optimization challenge due to the large number of burners that they contain. Imbalances caused by only a few mis-tuned burners can lead to reduced efficiency, premature tube failures, degraded catalyst, or constrained operation with changing fuel composition. ZoloSCAN provides the solution via real-time, in-furnace measurements of temperature, 02, H20 and CO allowing the operator to maintain target-firing profiles, deliver uniform fuel/air ratios, and improve safety margins.
Reforming
ACCURATE END-POINT DETECTION.
End-point detection in the BOF steel-making process is critical to optimal efficiency. Ending the oxygen blow too late oxidizes iron which reduces yield and wastes oxygen. Ending the blow too early can cause the steel carbon specification to be missed, requiring a costly re-blow. End-point can be determined by correlating the rate of change of off-gas concentrations (CO and CO2) and in some cases temperature to final bath carbon levels. Existing off-gas analytical methods are too slow (typically 30-45 seconds) to allow live end-point timing and can only be used for predictive control. Only ZoloSCAN offers a near real-time update rate (2 seconds) of CO, CO2, 02, H20 and temperature, for closed-loop control and optimization of the end of blow in the BOF process.
DOWNLOAD LITERATURE
Basic Oxygen Furnace
Installation Base
IMPROVED HEAT RATE.
Competition from renewable and natural gas-fired generation, plus more stringent emissions requirements for NOx, CO and CO2, are forcing improvements in coal power plant efficiency and emission reductions. The most cost-effective way to increase efficiency and reduce emissions is to optimize the combustion process. The ZoloSCAN laser-based combustion monitoring system provides in-furnace measurements of temperature, H20, CO and 02 with spatial resolution to identify and correct localized imbalances, thereby enabling emissions reductions and efficiency gains.
DOWNLOAD LITERATURE
Power Generation
OPTIMIZED ZONE CONTROL.
Efficient operation of steel reheat furnaces requires accurate control of air-to-fuel ratios in each heating zone. The consequences of deviations from setpoint, or poor ratio control, are lower fuel efficiency and scale formation from excess combustion air, or unburned CO and safety concerns from insufficient combustion air. ZoloSCAN, using real-time, laserbased sensing, measures 02, CO, H20 and temperature in each combustion zone. ZoloSCAN is not a spot measurement technology. The laser measures across the entire furnace to deliver accurate and reliable analysis of products of combustion. The data, when delivered to the PLC or DCS can be used for closed-loop zone ratio control or general combustion monitoring. The results are lower fuel consumption, reduced scale formation and a safer operation.
DOWNLOAD LITERATURE
Multiple species in a single beam
Multiple paths in a single system
Minimal maintenance
ZOLO technology
Zolo ZMUX technology enables simultaneous temperature, CO, H2O and O2 or CO2 quantification on a single measurement path for ultimate value and precision in combustion control.
Traditional Sensors: Single-point sensors (e.g. ZrO2) and single-path, single-species, laser-based sensors do not sample the furnace in a representative way. As a result, the cost to provide equivalent information is excessive or they suffer from insufficient data to optimize the process fully. Ultimately, the result is extra cost, complexity and maintenance to monitor combustion products or an under-optimized process.
Zolo’s unique fiber-coupled architecture allows up to 24 measurement paths from a single system for ultimate value in the spatial control of a furnace.
Traditional Sensors: Each sensor is its own system and independently calibrated, leading to both increased complexity and spatially-dependent uncertainty in measurement uniformity.
If you can clean an A/C filter and wipe a window, you can maintain the ZoloSCAN. Rugged hardware, auto-aligning heads, and an easy hinged window allow operations to focus on running the furnace.
Traditional Sensors: Complicated maintenance processes are common: Air or N2 purging, re-alignment after startup or shutdown, finicky operation in environments with dynamic wall warpage, calibration with standard compressed gas mixtures, and unplugging clogged extractive lines are common maintenance requirements for alternative technologies.
View our installation map
About ZOLO
Explore ZOLO
Digital Data to your DCS
OPC or Modbus communication protocols
Field Calibration not required
Automated self-check of system every 24 hours
Locally Installed Cabinet
Hazardous location capable
Furnace Access
Retrofit your existing sight ports
Multiple Paths
Multiple measurement locations per system
Reliable reporting
SensAlign™ self-aligning heads for continuous reporting
Reduced installation costs
Up to 50% cost reduction vs original ZoloSCAN system
Minimal Conduit
Conduit and electronics to one side of furnace only
Multiple species from a single path
Temperature, O2, CO, CH4 and H2O
Passive Mirror
No electronics or conduit to run
Hover over the + for more information
ZoloSCAN 2