Ready for what's next?
Tap to see the path to full-stack accelerated computing platforms for generative AI workloads.
See more
I want to
build a new
data center
I want to
retrofit an existing data center
In partnership with
Building your
AI Factory.
1.2MW
Cluster
360 kW
Cluster
Home
Retrofit
Why Vertiv?
Up to 20KW per rack, Air cooled
41kW per
rack air cooled
2.3MW design with 36 racks
3.5MW Design
with 54 Racks
5MW Design with 72 Racks
40kW per
rack with rear-door
heat exchangers (RDHX)
6.3MW Design
with 110 Racks
5MW Design
with 88 Racks
360kW Cluster at
20kW per rack air cooled
18
Racks (s)
Total IT Load 358kW
18Racks at 20KW per rack.
Featuring the NVIDIA DGX H100 System,
this full data center environment designed for a 360kW solution with 2N redundancy.
1.2MW
Cluster
360 kW
Cluster
Solving the Complexities
of the AI Revolution
The Vertiv and NVIDIA co-development partnership enables customers to transform traditional data center architectures into AI Factories capable
of powering AI applications across the enterprise.
Working together, we’re setting a
future-forward roadmap for
technical co-development and enabling the deployment of accelerated computing at scale.
See more
Home
In partnership with
Medium space applications
Why Vertiv?
In-rack
liquid-to-liquid solution
High density
liquid-to-air solution
Large space applications
New Build
Home
Find your solution.
Want a full liquid-to-liquid solution with a small footprint? This solution doesn’t need additional floor space for coolant distribution units and leverages existing air-cooling for the remaining portion of the heat load.
Liquid to air direct-to-chip retrofit.
Small HPC minimal retrofit for chilled water system
Heat removal
from server
Brown field
100kW
TotalSolution
Capacity
Small Space.
Big Performance.
1
Rack(s)
Heat removal
from room
100kW
Load per rack
Large space applications
Medium space applications
Small space applications
Small space applications
Vertiv can help you:
Liquid-to-liquid solution with supplemental perimeter
air cooling
Liquid-to-liquid solution with heat reuse
Low cost
liquid-to-refrigerant solution
High capacity
1.4MW solution
with supplemental perimeter
air cooling
High capacity 1.2MW solution with heat reuse
High density
air-cooled
solution with
DX heat rejection
This full data center environment is designed for
a 360kW solution with 2N redundancy,
using NVIDIA DGX H100 System.
Rack Density: 7 racks at 41kW, 1 rack at 30kW, 2 racks at 20kW
Total IT Load 358kW
10
Racks (s)
360kW Cluster at up to 41kW
per rack air cooled
Designed for a 360kW solution with 2N redundancy,
this full data center environment uses the
NVIDIA DGX H100 System.
Rack Density: 7 racks at 41kW, 1 rack at 30kW, 2 racks at 20kW
Total IT Load 358kW
10
Racks (s)
360kW Cluster at up to
41kW per rack with rear-door heat exchangers (RDHX)
This full data center environment is designed for a
5MW solution with distribution redundancy and uses
four NVIDIA DGX SuperPOD™.
4x 1.2MW NVIDIA DGX SuperPOD™
Rack Density: 64 racks at 73kW, 24 racks at 12kW
88
Racks
Total IT Load 4,960kW
(1240kW per POD)
Designed for a 6.2MW solution with distribution redundancy, this full data center environment features
five NVIDIA DGX SuperPOD™.
5x 1.2MW NVIDIA DGX SuperPOD™
Rack Density: 80 racks at 73kW, 30 racks at 12kW
110
Racks
Total IT Load 6,200kW
(1240kW per POD)
Featuring two NVIDIA DGX SuperPOD™ systems,
this full data center environment is a 2.3MW solution
with 2N redundancy.
2x 1.2MW NVIDIA DGX SuperPOD™
Rack Density: 16 racks at 132kW, 20 racks at 12kW
36
Racks
Total IT Load 2,352kW
(1176kW per POD)
A full data center environment designed for a 3.5MW solution with distribution redundancy. This system uses three
NVIDIA DGX SuperPOD™.
3x 1.2MW NVIDIA DGX SuperPOD™
Rack Density: 24 racks at 132kW, 30 racks at 12kW
54
Racks
Total IT Load 3,528
With four NVIDIA DGX SuperPOD™, this full data center environment is designed for a 5MW solution
with distribution redundancy.he .PDF says “distribution,” but do we mean “distribute
4x 1.2MW NVIDIA DGX SuperPOD™
Rack Density: 32 racks at 132kW, 40 racks at 12kW
72
Racks
Total IT Load 4,960kW
(1240kW per POD)
Design both power and cooling together to optimize AI infrastructure.
Dial up power efficiencies. Eliminate stranded
power by aligning AI clusters to data center
‘capacity blocks.’
Consider total cost of ownership, redundancy, and blast radius in AI power and cooling designs, and the tradeoffs among them.
Handle AI workload surges though system-level controls and power and cooling buffers.
Design for a mix of liquid and air cooling,
which have a combined and interdependent
impact on the ability to remove heat.
Design for the future. AI powerdensity will rapidly grow toward 500kW per rack.
For facilities that are unable to change existing
architectures and do not have chilled water available
on site, this solution offers a path to introducing liquid cooling into the existing space.
Liquid to air direct-to-chip retrofit.
Small HPC minimal retrofit
Heat removal
from room
Heat removal
from server
Brown field
88kW
Load per rack
88kW
TotalSolution
Capacity
1
Rack(s)
No water.
No problem.
Intended for retrofit of a data center with existing infrastructure and Vertiv cooling systems,
this budget-friendly solution can leverage existing
refrigerant piping and heat rejection
Liquid to refrigerant direct-to-chip
retrofit-optimized row.
Mid-sized HPC cost-optimized retrofit, chiller included
Heat removal
from room
Heat removal
from server
Brown field
100kW
Load per rack
400kW
TotalSolution
Capacity
4
Rack(s)
Power that doesn’t heat up your budget.
This solution maintains and optimizes the existing footprint while maintaining room neutrality by combining the use of direct-to-chip liquid cooling with a rear door heat exchanger.
Liquid to liquid direct-to-chip with heat reuse.
Mid-sized HPC with increased heat capture.
Heat removal
from room
Heat removal
from server
Brown field
Green field
100kW
Load per rack
400kW
TotalSolution
Capacity
4
Rack(s)
Putting the fit
in retrofit.
This solution retrofits existing air-cooled environments without disrupting existing workloads by incorporating
rear-door heat exchangers with refrigerant-based indoor split chillers. It also incorporates existing Vertiv™ Liebert® DSE cooling units and reuses the existing refrigerant piping and heat rejection. It doesn’t require chilled water loops on site.
High density air-cooled retrofit
Mid-sized HPC pragmatic retrofit for air-cooled computer rooms, chiller included.
Heat removal
from room
Heat removal
from server
Brown field
Green field
40kW
Load per rack
160kW
TotalSolution
Capacity
4
Rack(s)
An upgrade
made easy.
Intended to replace and optimize existing footprints for
high-density and AI applications. The solution combines
the use of liquid cooling direct-to-chip with air cooling
to cover the remaining capacity.
Liquid to liquid direct-to-chip for
early adoption.
Mid-sized HPC low complexity retrofit with air-cooling.
Heat removal
from room
Heat removal
from server
Brown field
100kW
Load per rack
500kW
TotalSolution
Capacity
5
Rack(s)
More power.
Same space.
Intended for large, new deployments that require heat capture for room neutrality, this solution combines the use of direct-to-chip liquid cooling with a rear door heat exchanger.
Liquid to liquid direct-to-chip with
heat reuse at scale
Large HPC preserving room neutrality.
Heat removal
from room
Heat removal
from server
Brown field
Green field
100kW
Load per rack
1200kW
TotalSolution
Capacity
12
Rack(s)
Neutrality
made easy.
Intended for large, new deployments, this solution combines the use of direct-to-chip liquid cooling with existing air cooling to cover the remaining capacity.
Liquid to liquid direct-to-chip at scale.
Large HPC building towards scale.
Heat removal
from room
Heat removal
from server
Brown field
Green field
100kW
Load per rack
1400kW
TotalSolution
Capacity
14
Rack(s)
XL Peace of Mind.
7MW Design
with 108 Racks
See more
A full data center environment designed for a
7MW solution with 4 to make 3 redundancy, using six
NVIDIA DGX SuperPOD™ systems utilizing the NVIDIA GB200 NVL72 platform. The latest end-to-end power and cooling solution with OCP-compliant components.
6x 1.2MW NVIDIA DGX SuperPOD™
48 racks at 130kW, 48 racks at 14kW
108
Racks
6,912kW (1,152kW per POD)
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
See more
Select a build below
Paired to perform.
See more
Vertiv™
SmartRun
See more
Vertiv™
KeySource
Infrastructure Solutions
New Build or Retrofit Designs
Multiple Deployment Options
Fast Repeatable Deployment
Power, Cooling, and Services
Grid to Chip
View in 3D
Select a higlighted product for more info.
High-Density Data Center
Traditional
Data Center
Services
Home
Traditional Solutions
See more
Prefabricated
Data Center
See more
Vertiv™
Timbermod
See more
Vertiv™
SmartMod™
MAX DX
See more
Vertiv™
SmartMod™
High Density Solutions
See more
AI-Ready
Data Center
for Polar
See more
Vertiv™
Power Module
See more
Vertiv™ PowerNexus
Services
See more
High Density
Data Center
See more
Traditional
Data Center
See more
Services
See more
Services
Infrastructure
Solutions Services
See more
Services
Liquid
Cooling Services
See more
Services
Thermal
Management
Services
Home
Power Management
Power Controls
Energy Storage
Switchgear & Power Distribution
Power Conversion/UPS
Grid to Chip
View in 3D
Select a higlighted product for more info.
High-Density Data Center
Traditional
Data Center
Power Control
Power Distribution
Power
Solution
Power Conversion
Services
Energy
Storage
Power Control
Power Distribution
Power Conversion
Services
Energy Storage
See more
Energy Storage
Vertiv™
Power Module
Fuel Cell Solution
See more
Energy Storage
Vertiv™
EnergyCore Lithium
Battery Cabinet
See more
Energy Storage
Vertiv™ DynaFlex
Battery Energy
Storage System
See more
Energy Storage
See more
Power Conversion / UPS
Vertiv™
PowerDirect IT Rack
See more
Power Conversion / UPS
Vertiv™
APM2 UPS
See more
Power Conversion / UPS
Vertiv™ Trinergy
Power Center
See more
Power
Conversion/
UPS
See more
Power Distribution
Vertiv™ PowerBar
Busway
See more
Power Distribution
Vertiv™
PPC Power
Distribution Unit
See more
Power Distribution
Vertiv™ Static
Transfer Switch
See more
Power Distribution
Vertiv™ PowerBoardSwitchgear
See more
Power
Distribution
Power Control
See more
Power Control
See more
Services
Power
Management
Services
See more
Power Control
Vertiv™
Energy Power
Management Systems
See more
Power Distribution
Vertiv™ PowerBar
Busway
See more
Energy Storage
Vertiv™
EnergyCore Lithium
Battery Cabinet
See more
Power Conversion / UPS
Vertiv™ Trinergy
Power Center
See more
Power Distribution
Vertiv™ PowerBoardSwitchgear
See more
Integrated Solutions
Vertiv™
PowerNexus
See more
Power Solution
Thermal Management
Thermal Control
Heat Rejection and Reuse
Air Cooling
Liquid Cooling
Chip to Heat Reuse
View in 3D
Select a higlighted product for more info.
High-Density Data Center
Traditional
Data Center
Thermal Control
Heat Rejection and Reuse
Services
Air Cooling
Hybrid Cooling
Liquid Cooling
Home
See more
Air Cooling
Liebert® CWAThermal Wall
See more
Air Cooling
Liebert® CW Chilled Water Cooling System
See more
Air Cooling
Vertiv™ Liebert®
DSE Packaged
Free-Cooling Solution
See more
Air Cooling
Liebert® DS
Direct Expansion
Cooling System
See more
Air Cooling
Liebert® DSE
Free Cooling Economization System
Cost: Up to 15% TCO improvement
See more
Air Cooling
See more
Heat Rejection and Reuse
Vertiv™ Liebert® MC Microchannel Coil Condenser
See more
Heat Rejection and Reuse
Liebert® MCVHigh DensityMicrochannel Condenser
Cost: Up to 15% TCO improvement
See more
Heat Rejection and Reuse
Vertiv™ CoolLoop
Trim Cooler
Efficiency: Up to 70% energy savings
Space: Up to 40% increase in density
See more
Heat Rejection and Reuse
Vertiv™
Liebert® AFC
Free-Cooling Chiller
Efficiency: Up to 20% energy savings
See more
Heat Rejection
and Reuse
See more
Thermal Control
Liebert® iCOM™
CWM Chilled Water
Plant Manager
See more
Thermal Control
Liebert®
iCOM™ Cooling
Unit Control
See more
Thermal Control
Liebert® iCOM™-S
Advanced Thermal
Monitoring and
Control Software
See more
Thermal Control
See more
Services
Liquid Cooling Services
See more
Services
Thermal
Services
Hybrid Cooling
See more
Vertiv™ CoolPhase
Flex Packaged
Cooling System
Speed: Up to 50% faster deployments
See more
Liquid Cooling - Coming Soon
Vertiv™
CoolCenter
Immersion Systems
See more
Liquid Cooling
Vertiv™ CoolChip
Fluid Network
In-Rack Manifolds
See more
Liquid Cooling
Liebert®
DCD Rear Door
Heat Exchangers
See more
Liquid Cooling
Vertiv™ CoolPhase
CDU Coolant
Distribution Units
Cost: Up to 15% TCO improvement
See more
Liquid Cooling
Vertiv™ CoolChip
CDU Coolant
Distribution Unit
Efficiency: Up to 15% Energy Savings
See more
Liquid Cooling
The world depends on data
we power and cool™
Thermal
Management
Power
Management
Infrastructure
Solutions
Vertiv 360AI
